Troubleshooting startup problems 14-3
Normal startup sequence
Standard 1.0 Option 11 EC Installation and Maintenance Guide November 1999
Normal startup sequence
Introduction
When you power up the EC 11, the single board Enhanced
MMP40 or MMP40 computer must
first initialize itself and perform self-diagnostics
start up the other system elements (for example, the disk
subsystem) and perform diagnostics on them
load the Meridian Mail operating system and the MMI
The single board Enhanced MMP40 or MMP40 computer
initialization phase can be monitored using the hexadecimal
display on the card. The startup can also be monitored using
the text displayed on the terminal. The following sections
describe the hexadecimal display and the progression through
a startup sequence.
CAUTION
Risk of equipment damage
To reduce stress on the system, use the
reset button on the faceplate of the
Enhanced MMP40 or MMP40 card to
restart the system instead of powering the
cabinet off and on. Reset node 1 first,
then node 2 in sequence, as applicable.
However, if there is a question regarding
the state of the system after the system
reset, power off the system, wait 10
seconds, then power it back on to restart.