Configuring the Meridian 1 Option 11 switch 10-3
Entering overlays
Standard 1.0 Option 11 EC Installation and Maintenance Guide November 1999
Entering overlays
Preparation
Check the configuration of the software and hardware on the
Meridian 1 Option 11 switch before installing Meridian Mail.
See Chapter 11 of this manual, “Install the EC 11 to Meridian
1 Option 11 switch interface.”
Have the following documentation on hand:
• X11 Input/Output Guide NTP 553-3001-400
• Circuit Pack Option Settings NTP 553-2201-211
• Circuit Pack Installation and Testing NTP 553-3001-211
Skillset required
In order to complete the procedures in this section, it is
assumed that you are a technician who is both skilled and
experienced in the operation of the Option 11 switch.
Terminal operation
Log on to the Meridian 1 before you load any of the overlays.
Load the overlay with the command LD nn, where nn is the
number of the overlay (example LD 22).
In the tables showing your responses to prompts from
Meridian 1 overlays, respond only to the prompts that are
shown. If you see a prompt on the terminal that is not in the
table, press <cr> until you see the next prompt that is in the
table.
After the last prompt shown in the table, press <cr> until the
first prompt (usually REQ) appears again before exiting the
overlay. If you do not do so, the information you entered will
be discarded when you exit the overlay.
When the first prompt (usually REQ) appears again, enter
**** or END, followed by <cr>, to exit an overlay.