13-20 Starting up and configuring Meridian Mail
Starting up Meridian Mail
Standard 1.0 Option 11 EC Installation and Maintenance Guide November 1999
Starting up Meridian Mail
Starting up
With the EC 11 still powered down, follow these steps.
Note: If any problems occur during startup, see Chapter 14,
"Troubleshooting startup problems."
Step Action
1 Power on the EC 11’s administration terminal,
printer, and other peripheral devices.
2 On the administration terminal, press <Ctrl> and
<Print Screen> at the same time to turn on
automatic printing.
Note: The <Print Screen> key may be labeled
differently on your keyboard.
Result: The word “Aut” appears at the bottom of the
terminal screen, indicating that the terminal is in the
automatic printing mode. Automatic printing allows
you to capture a printout of the startup messages
when you power on the EC 11. See Chapter 14,
"Troubleshooting startup problems."
3 Before you power up the EC 11, examine the table
here so that you can verify the proper behavior of
the LEDs visible on the front of each module and the
hexadecimal display on the front of the Enhanced
MMP40 or MMP40 CPU(s).
Location of LED Color Behavior
Power supply Batt
Power supply DC
Green
Green
On while DC backup battery
power is OK.
On while the breaker is on and
output from the power supply to
the backplane is OK.
Voice processor Green On while power to the card from
the backplane is on.
Utility card Green On while the card is enabled. The
LED does not illuminate until the
Enhanced MMP40 or MMP40
enables the Utility card.