Seagate ST3400071FC Guia do Utilizador Página 510

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 718
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 509
22.104
Command Line Interface Reference InForm OS Version 2.2.4
The following examples display both standard and detailed information about SFPs attached
to ports:
NOTES
See Restrictions on page 10.17 for important information regarding port modes and port pair
protection.
cli% showport -sfp
N:S:P -State- -Manufacturer- MaxSpeed(Gbps) TXDisable TXFault RXLoss DDM
0:0:1 OK FINISAR_CORP. 2.10 No No No Yes
0:0:2 OK FINISAR_CORP. 2.10 No No Yes Yes
0:3:2 OK SIGMA-LINKS 2.10 No No Yes Yes
1:0:1 OK FINISAR_CORP. 2.10 No No No Yes
1:0:2 OK FINISAR_CORP. 2.10 No No Yes Yes
cli%
root@enodea5:~# showport -sfp -d
------------Port 0:0:2------------
N:S:P : 0:0:2
State : Degraded
Manufacturer : PICOLIGHT
Part Number : PL-XPL-VE-S24-31
Serial Number : 425EF1E6
Revision : N/A
MaxSpeed(Gbps): 2.10
Qualified : No
TX Disable : --
TX Fault : --
RX Loss : --
RX Power Low : No
DDM Support : No
----------Port 1:3:1-----------
N:S:P : 1:3:1
State : OK
Manufacturer : FINISAR_CORP.
Part Number : FTLF8519P2BNL
Serial Number : U76031S
Revision : A
MaxSpeed(Gbps): 2.10
Qualified : Yes
TX Disable : No
TX Fault : No
RX Loss : No
RX Power Low : No
DDM Support : Yes
Vista de página 509
1 2 ... 505 506 507 508 509 510 511 512 513 514 515 ... 717 718

Comentários a estes Manuais

Sem comentários