22.18
Command Line Interface Reference InForm OS Version 2.2.4
Specifying the –d option provides more detailed information about the drive cages. See the
following T-Class Storage Server example for
cage0:
cli% showcage -d cage0
Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model Side
0 cage0 0:1:1 0 1:1:1 0 40 24-33 2.05 2.05 DC4 n/a
-----------Cage detail info for cage0 ---------
Position: ---
Fibre Channel Info PortA0 PortB0 PortA1 PortB1
Link_Speed 4Gbps 0Gbps 0Gbps 4Gbps
----------------------------------SFP Info-----------------------------------
FCAL SFP -State- --Manufacturer-- MaxSpeed(Gbps) TXDisable TXFault RXLoss DDM
0 0 OK FINISAR CORP. 4.20 No No No Yes
0 1 OK FINISAR CORP. 4.20 No No Yes Yes
1 0 OK FINISAR CORP. 4.20 No No Yes Yes
1 1 OK FINISAR CORP. 4.20 No No No Yes
Interface Board Info FCAL0 FCAL1
Link A RXLEDs Green Off
Link A TXLEDs Green Green
Link B RXLEDs Off Green
Link B TXLEDs Green Green
LED(Loop_Split) Off Off
LEDS(system,hotplug) Green,Off Green,Off
-----------Midplane Info-----------
Firmware_status Current
Product_Rev 2.05
State Normal Op
Loop_Split 0
VendorId,ProductId 3PARdata,DC4
Unique_ID 1062010000001C00
Power Supply Info State Fan State AC Model
ps0 OK OK OK POI
ps1 OK OK OK POI
ps2 OK OK OK POI
ps3 OK OK OK POI
-----Magazine Info----- ---State---
Mag SysLED HplLED Disks LoopA LoopB
0 Green Off 4 Ready Ready
1 Green Off 4 Ready Ready
2 Green Off 4 Ready Ready
...
9 Green Off 4 Ready Ready
-------------Drive Info------------- ----LoopA----- ----LoopB-----
Drive NodeWWN LED Temp(C) ALPA LoopState ALPA LoopState
0:0 2000001862c4e410 Green 31 0xe1 OK 0xe1 OK
0:1 2000001862c4e3f6 Green 31 0xe0 OK 0xe0 OK
0:2 2000001862c4e3bc Green 28 0xdc OK 0xdc OK
...
9:1 2000001862b9affb Green 30 0xa6 OK 0xa6 OK
9:2 2000001862b9b035 Green 27 0xa5 OK 0xa5 OK
9:3 2000001862b9b7b5 Green 25 0xa3 OK 0xa3 OK