Seagate ST3400071FC Guia do Utilizador Página 316

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 718
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 315
20.6
Command Line Interface Reference InForm OS Version 2.2.4
OPTIONS
–f
Specifies that the command is forced. If this option is not used, the command requires
confirmation before proceeding with its operation.
SPECIFIERS
<node:slot:port>
Specifies a node. This specifier can only be used with the remove subcommand.
<WWN_or_iSCSI_name>
Specifies a host’s WWN. This specifier can only be used with the remove and copy
subcommands. When used with the remove subcommand, this specifier can be repeated.
<WWN_or_iSCSI_name_pattern>
Specifies that the indicated WWN or iSCSI name is treated as a glob-style pattern. See Glob-
Style Pattern on page 2.4 for more information.
<src_node:slot:port>
Specifies the source port when exporting VLUNs. This specifier can only be used with the
copy subcommand.
<dest_node:slot:port>
Specifies the destination port when exporting VLUNs. This specifier can only be used with
the
copy subcommand.
RESTRICTIONS
If the <WWN_or_iSCSI_name> specifier is not issued with the remove subcommand, all
inactive hosts on the specified port and their LUNs are removed.
If the <node:slot:port> specifier is not used with the remove subcommand, all
inactive hosts in the system and their LUNs are removed.
EXAMPLES
The following example displays the creation of a host on port 0:2:1 for the export of VLUNs
from port 2:1:1:
cli% servicehost copy 2:1:1 20000200000CF790 0:2:1
Are you sure you want to run servicehost?
select q=quit y=yes n=no: y
Vista de página 315
1 2 ... 311 312 313 314 315 316 317 318 319 320 321 ... 717 718

Comentários a estes Manuais

Sem comentários