18.2
Command Line Interface Reference InForm OS Version 2.2.4
COMMAND
promotesv
DESCRIPTION
The promotesv command copies the differences of a snapshot back to its base volume or any
RW parent in the same VV family tree, allowing you to revert the base volume to an earlier
point in time.
SYNTAX
promotesv [options] <virtual_copy_name>
AUTHORITY
Super, Edit
OPTIONS
-target
Copy the differences of the virtual copy to the specified RW parent in the same VV family
tree. The default is to copy the differences to the base volume.
This option cannot be used with the -halt option.
The virtual copy and the target of the promote must not be exported.
Only one promotesv operation is allowed at a time within a VV family tree.
–rcp
Allows the promote operation to proceed even if the base volume is currently in a Remote
Copy volume group, if that group has not been started. If the group has been started, this
command fails. This option cannot be used in conjunction with the
–halt option.
–halt
Cancel an ongoing snapshot promotion. Marks the base volume with the copy failed
status that can be rectified using the
promotevvcopy (see promotevvcopy on page 18.4)
command or by issuing a new instance of the
promotesv command. This option cannot be
used in conjunction with the
–rcp option.
SPECIFIERS
<virtual_copy_name>
Specifies the name of the virtual copy volume to be promoted, using up to 31characters.