Seagate ST318404LC Guia do Utilizador Página 55

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 67
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 54
Dell Compellent Confidential HP-UX Best Practices 11i v2 and 11i v1
Page|55
Boot from SAN (OS Boot Volume)
To boot from SAN, you would need to configure the Dell Compellent Storage Center presented LUN as a
bootable device path. We would achieve this with the command as follows.
Type: /opt/drd/bin/drd activate
OR
Type: setboot –p 0/2/1/0/4/0.236.0.0.0.0.0
(Where –p: represents configuring the path as the primary boot device and where either of the dual
paths may be used to identify the bootable device).
Upon reboot, the host will attempt to boot from this SAN LUN.
The HP-UX 11i v2 IgniteUX C.7.13.259 IINSTALLFS kernel (or newer) CONTAINS the
necessary drivers to detect Dell Compellent Storage Center presented FC LUNs during a
IgniteUX-based installation process. You may either install HP-UX directly to the Dell Compellent
Storage Center LUN via the IgniteUX interactive GUI or the drd process (outlined in DRD and creating a
Point in Time Copy, DRD and creating a Boot from SAN LUN).
HP-UX 11i v1 only operates on PA-RISC based architecture. This OS version DOES NOT
provide any support for drd tools nor provide any facilities to boot from SAN LUNs.
Vista de página 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 66 67

Comentários a estes Manuais

Sem comentários