ext_bus 45 255/0/3.0 iscsial CLAIMED INTERFACE iSCSI-SCSI Protocol Interface
In the scenario above, we have only setup only one (1) discovery IP address mapped to a
single interface on a quad port NIC. To ensure proper failover and redundancy in an
enterprise scenario, it is strongly recommended to establish one or more discovery IP addresses on the
host (OS) side; in accordance with mapping a secondary interface on a alternate NIC via a different
VLAN to the Dell Compellent Storage Center.
Adding LUNs
Having completed the procedures above, you can now add this connection to the Dell Compellent
Storage Center. Open the “Create Server” dialog and uncheck the “Only Show Up Connections” box and
let the screen refresh. The iqn for your server should appear in the dialog box.
If the iqn does not appear this latter dialog box, you will need to add the iqn manually.
Left-click the “Manually Define HBA” button, select the iSCSI radio button in the “Transport
Type” selection box and enter the known iqn into the “WWN or iSCSI Name:” text box, left-Click the
“Continue” button, then continue creating the server object per usual procedures. This procedure
should NOT be needed if using Dell Compellent Storage Center code 5.4.x or newer.
Complete the “Create Server” process, then map LUNs to the host. For purposes of this example, we
have created and mapped two (2) 50GB LUNs to the host. On the host, issue this command.
Type: ioscan –fnH 255/0
Class I H/W Path Driver S/W State H/W Type Description
==========================================================================
iscsi 0 255/0 iscsi CLAIMED VIRTBUS iSCSI Virtual Node
ext_bus 42 255/0/0.0 iscsial CLAIMED INTERFACE iSCSI-SCSI Protocol Interface
target 44 255/0/0.0.0 tgt CLAIMED DEVICE
disk 3 255/0/0.0.0.1 sdisk CLAIMED DEVICE COMPELNTCompellent Vol
ext_bus 43 255/0/1.0 iscsial CLAIMED INTERFACE iSCSI-SCSI Protocol Interface
target 45 255/0/1.0.0 tgt CLAIMED DEVICE
disk 4 255/0/1.0.0.1 sdisk CLAIMED DEVICE COMPELNTCompellent Vol
ext_bus 44 255/0/2.0 iscsial CLAIMED INTERFACE iSCSI-SCSI Protocol Interface
target 46 255/0/2.0.0 tgt CLAIMED DEVICE
disk 12 255/0/2.0.0.1 sdisk CLAIMED DEVICE COMPELNTCompellent Vol
ext_bus 45 255/0/3.0 iscsial CLAIMED INTERFACE iSCSI-SCSI Protocol Interface
target 47 255/0/3.0.0 tgt CLAIMED DEVICE
disk 13 255/0/3.0.0.1 sdisk CLAIMED DEVICE COMPELNTCompellent Vol
We see the LUNs presented from the Dell Compellent Storage Center to the host and would now need
to build the necessary devices files to support these LUNs. Issue the command.