Seagate Barracuda ATA II 100 Series Manual Página 17

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 39
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 16
10 Barracuda ATA II 100 Family Product Manual, Rev. A
1.7.2 Conducted noise
Input noise ripple is measured at the host system power supply across
an equivalent 80-ohm resistive load on the +12 volt line or an equivalent
15-ohm resistive load on the +5 volt line.
Using 12-volt power, the drive is expected to operate with a maximum
of 120 mV peak-to-peak square-wave injected noise at up to 10 MHz.
Using 5-volt power, the drive is expected to operate with a maximum
of 100 mV peak-to-peak square-wave injected noise at up to 10 MHz.
Note.
Equivalent resistance is calculated by dividing the nominal volt-
age by the typical RMS read/write current.
1.7.3 Voltage tolerance
Voltage tolerance (including noise):
1.7.4 Power-management modes
The drive provides programmable power management to provide great-
er energy efficiency. In most systems, you can control power manage-
ment through the system setup program. The drive features the following
power-management modes:
Active mode
The drive is in Active mode during the read/write and seek operations.
Idle mode
The buffer remains enabled, and the drive accepts all commands and
returns to Active mode any time disc access is necessary.
5V ± 5% 0.7 amps max
12V + 10%, – 5% 2.4 amps max
Power Modes Heads Spindle Buffer
Active Tracking Rotating Enabled
Idle Tracking Rotating Enabled
Standby Parked Stopped Enabled
Sleep Parked Stopped Disabled